HOME GUIDE OPERATIONS DOCS FAQ TECHNIQUES FORMATS INSTALL NEW TIPS WEB LINKS WADSWORTH

AP SA - Alignment - Reference free, Shift ||

(6/09/08)

PURPOSE

Shift aligns an image series. This operation together with operation 'AP RA' (rotational alignment) constitutes reference-free approach to alignment of 2D images. The detailed description of the method can be found in "Three-dimensional reconstruction of single particles embedded in ice". P.Penczek et al., Ultramicroscopy, 40 (1992) 33-53. An example of the SPIDER procedure implementing the alignment is included below.

SEE ALSO

VO EA [Vector Operation - Create Evenly Spaced Angles Document file]
VO MD [Vector Operation - angular Document file from 'AP MD' output]
AP SR [Alignment - reference free, Shift & Rotation ||]
AP RA [Alignment - Reference-free rotational alignment ||]

USAGE

.OPERATION: AP SA

.ENTER TEMPLATE FOR 2-D IMAGE NAME: img****
[Give the template name of the existing file series to be aligned.]

.DOCUMENT (WITH GROUP ASSIGNMENT): FALDOC
[Document file name produced by 'AP RA' or 'AP CA'.]

.GROUP NUMBER: 1
[Give 1 for output of 'AP RA' or any of valid group number coming from 'AP CA'.]

.CHECK 180 ROTATION (Y/N): N
[Answer 'Y' should be given only if the images to be processed were on previous step aligned by 'AP RA' or 'AP CA 'with option Half ring, which means that ACFs were aligned. Answer 'N' results in the speed up of this procedure.]

.DOCUMENT FILE: SALDOC
[This is one of the the two outputs produced by this procedure. It contains 6 columns:

1. File number.
Real file number to deal with gaps in file series.

2. Rotation angle. Image has to be rotated +angle to produce average. It is rewritten from the input doc. file with 180 deg. added if found to be needed by 'AP SA'.

3. Distance. Distance from the total rotational average. It is rewritten from the input.

4. X shift.

5. Y shift. After rotation image has to be shifted +X, +Y to produce the average.

6. Distance. Distance from the average found by 'AP SA'.]

.OUTPUT FILE: AVIMA001
[Output: Average image as found by the procedure.]

NOTES

  1. Images do not have to have power-of-two dimensions. Only for non-SGI systems: The image dimensions MUST be factorisable with prime numbers smaller than 23! (See 'FT' manual chapter). The power-of-two numbers fulfill this requirement. The less surrounding noise is included the faster operation runs and results are better.

  2. Please note that shift parameters produced by this operation are given with the proper signs. To shift the images afterwards these parameters should be applied directly (without sign reversion). To combine parameters given by repeated alignment 'SA P' operation has to be used. The angle signs used for 3-D reconstruction from tilted series have to be reversed.

  3. The operation is used by the refal.sys procedure.

  4. Implemented by Paul Penczek.

SUBROUTINES

SAQB, SAQB_P, SAQB_F, UPDTF, COP, MLC, SHFC_2, SH180_2, SHFM_2, CR180_2, MJC, FMRS_2, FMR_1, FFTMCF, FINDMX, ENFR_2, RTQ, QUADRI

CALLER

UTIL4
>
>  Example of a SPIDER procedure implementing reference-free alignment
>  of the series of images using 'AP SA' and 'AP RA' operations. The procedure
>  uses following strategy: initially all the particles are centered
>  approximately using shift alignment (AP SA) with 180 degrees
>  rotation check.  This is followed by a number (up to 9 in this version)
>  steps of shift and rotational alignment of the input data series.
>  After each such step the resulting average is centered using
>  phase approximation of the center of gravity operation (CG PH).
>  This procedure works for consecutively numbered images only, but the 
>  numbering does not have to start with one.


;  b02.sup  -  ALIGNMENT  01/09/98
;  ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^

;  Important notes:

;  (1) To start the procedure one has to modify the input file names
;  and specify input parameters: number of steps required, number
;  of particles and ring numbers used by APRA (determined by the
;  expected radius of the particle).

;  (2) The shift alignment step does not enforce centering of the average
;  by itself.  The average produced by AP SA (AVS*** in the following
;  procedure) has to be centered explicitly.  In the procedure operation
;  CG PH (phase approximation of the center of gravity) is use for
;  this purpose.  It is not guaranteed to work for all the possible
;  shapes and it is advisable to verify whether the average was
;  shifted correctly.  If not, the operation can be easily replaced
;  by the other mean of centration (for example croscorrelation
;  with low-pass filtered disk).

;  (3) Please note that CG PH will NOT work correctly for images
;  with inverted contrast (dark particle on bright background).
;  In such case either contrast of the particles has to be inverted,
;  or the contrast of the average before application of CG PH.

;  (4) VERY IMPORTANT:  if you want to start the procedure again
;  from the beginning you have to either delete previously produced
;  document files or change the names of the existing file.

;  (5) The procedure can be easily restarted to make additional steps
;  of alignment. If initially procedure was ran for 5 steps of alignment
;  than it is enough to change register X61 in the input block
;  to the new iterations limit, remove part of the procedure between "End
;  of the input parameters" block to the main do-loop LB9 and change
;  in this line "2" to "6" (in this case, in general to the next step
;  number).

;  (6) The procedure makes it possible to calculate the current resolution
;  of 2D average. The code has to be added by the user in the place marked.

; %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%

;  DESCRIPTION OF THE FILE NAMES USED:

;  The input data is the series of images
;  data/PAR****    1-1210

;  The output data is the separate series of images calculated after
;  each step of alignment
;  ali/PUR*****
;  first digit stands for the number of alignment step, the remaining
;  four digits are reserved for the particle number.
;
;  Program uses the following document files:
;
;  FALS - dummy file to initialize first shift alignment containing
;         particle numbers
;
;  APSA*** - ending with the number indicating the number of alignment
;            step. This is the document file produced by the shift
;            alignment (AP SA). Details are in the manual chapter APSA.MAN.
;
;  APRA*** - ending with the number indicating the number of alignment
;            step. This is the document file produced by the rotational
;            alignment (AP RA). Details are in the manual chapter APRA.MAN.
;
;  PRM***  - ending with the number indicating the number of alignment
;            step. This is the document file containing the combined alignment
;            parameters for each particle after all alignment steps made
;            up to this one. When applied to the initial (input) data
;            they will produce the aligned and centered series of particles.
;            The angles (after reversing the sing) can be used in 3D
;            reconstruction.
;            This file contains four columns:
;              1                      2        3        4
;            particle number        angle    X shift   Y shift
;
;  SHIFTS -  contains X,Y shifts needed to center the average calculated
;            after each shift alignment.

;  The procedure requires specification of the following input: 
;  X61 - number of alignment steps 
;        First is the initialization step - shift only (APSA)
;        Next X61-1 double steps are made - (rotation + shift)

;  X62 - number of particles
;  X63 - first particle number
;  X41 - first ring number (required by AP RA)
;  X42 - last ring number (required by AP RA)

; %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%

;  Beginning of the procedure.
;  -------------------------; 

; Specify input parameters:
;-------------------------------------------------------------------; 
;  X61 - number of alignment steps 
;        First is the initialization step - shift only (APSA)
;        Next X61-1 double steps are made - (rotation + shift)
X61=5
;  X62 - number of particles
X62=2530
;  X63 - first particle number
X63=1

;  X41,X42 - specification of first and last ring numbers
X41=5
X42=29

; End of the input parameters block.
;-------------------------------------------------------------------; 

;  X71 - current step number
X71=1
; FALS is a dummy document file containing particle numbers in the first
;      column. In general they do not have to be in consecutive order
;      neither begin from one.
X31=0.0
X32=1.0
DO LB1 I=1,X62
  SD X0,X0,X31,X31,X32
  RESULTs/FALS
LB1

SD E
RESULTs/FALS

; First shift alignment with 180 degs check to center all the particles.
AP SA
data/PAR001
RESULTs/FALS
1
Y
RESULTs/APSAX71
RESULTs/AVSX71

;   Calculate center of gravity using CG PH to center the average.

CG PH,X21,X22
RESULTs/AVSX71
SD X71,X21,X22
SHIFTS

;  X21 and X22 contain integer shift values which will be used to
;  center all the images.

;  Shift and rotate all the input data (using center correction
;  shifts found by CG PH).  The resulting file series will be used
;  in the next alignment step.

DO LB2 I=1,X62
  ;               For short image series use UD IC instead on remove ";" signs
  ;               from UD ICE lines in the procedure.
  UD S,X0,X31,X32,X33,X34,X35,X36
  RESULTs/APSAX71
  X34=X34-X21
  X35=X35-X22
  X91=X71*10000+X31
  RT SQ
  data/PARX31       
  ali/PUR00X91
  X32
  X34,X35
  SD X0,X31,X32,X34,X35
  RESULTs/PRMX71
LB2

SD E
RESULTs/PRMX71

;UD ICE
;RESULTs/APSAX71


;  Main loop LB9 - make X61-1 steps of alignment.
;  ---------------------------------------------; 

DO LB9 I=2,X61

  X71=X0
  X70=X71-1
  X93=X70*10000+X63
  X92=X70*10000+X62

  ;                     Rotational alignment
  AP RA
  ali/PUR*****
  X93-X92
  X41,X42
  (1)
  F
  RESULTs/APRAX71

  ;                     Shift alignment
  AP SA
  ali/PUR00X93
  RESULTs/APRAX71
  (1)
  N
  RESULTs/APSAX71
  RESULTs/AVSX71

  ;   Calculate center of gravity using CG PH to center the average.

  CG PH,X82,X84,X21,X22
  RESULTs/AVSX71
  SD X71,X21,X22
  SHIFTS

  ;  At this stage it is advisable to remove the aligned image series
  ;  aligned during the provious step for the sake of the disk space.

  ;DE A
  ;ali/PUR00X93

  ;  Rewrite the whole image series combining alignment parameters
  ;  and applying them to the input series PAR****.  A new, aligned
  ;  and centered series PUR***** is produced.
  ;
  DO LB8 I=1,X62
       ;               For short image series use UD IC instead on remove ";" signs
       ;               from UD ICE lines in the procedure.
       UD S,X0,X81,X82,X84,X85
       RESULTs/PRMX70
       UD S,X0,X31,X32,X33,X34,X35,X36
       RESULTs/APSAX71
       SA P,X82,X84,X85,X32,X34,X35,X52,X54,X55
       X54=X54-X21
       X55=X55-X22
       X91=X71*10000+X81
       RT SQ
       data/PARX81     
       ali/PUR00X91
       X52
       X54,X55
       SD X0,X81,X52,X54,X55
       RESULTs/PRMX71
  LB8
  ;UD ICE
  ;RESULTs/PRMX70


  ;   The following block can be used to calculate current averages
  ;   and estimate the resolution.
  ;X93=X71*10000+X63
  ;X92=X71*10000+X62
  ;AS R
  ;ali/PUR00X93
  ;X93-X92
  ;E
  ;AASX71
  ;AAVX71
  ;ABSX71
  ;ABVX71

  ;  Calculate the resolution using AASX71 and ABSX71.
  ;  Use your own procedure ..... 

LB9
EN

;  End of the procedure.


© Copyright Notice /       Enquiries: spider@wadsworth.org