Microcystin

Application materials are available for laboratories to apply for ELAP certification for Total Microcystins.  Certification for Total Microcystins will be offered in the Drinking Water and Non-Potable Water categories using Total Microcystins by Environmental Protection Agency (EPA) Method 546 – Determination of Total Microcystins and Nodularins in Drinking Water and Ambient Water by Adda Enzyme-Linked Immunosorbent Assay (ELISA) (ELAP method number 9168).

Any laboratories currently performing Total Microcystin analysis using ELISA on Drinking Water and Non-Potable Water samples originating from New York State will need to submit  either or both a primary application in the Potable (Drinking) and Non-Potable Water category and supporting documentation (see below) by Friday, May 4, 2018.  Any laboratory that is currently performing total Microcystin testing and that has submitted a timely application for certification, will be granted interim approval until the application is fully processed by ELAP.  A laboratory will be required to have an on-site assessment performed prior to full certification being granted.

Form 108 - Potable Water - Primary

Form 109 - Non-Potable Water - Primary

Required Supporting Documentation

  1. Standard Operating Procedure
  2. Evidence of a Qualified Technical Director

Technical Directors for Total Microcystin Analysis shall be:

  • an individual with requisite credentials and experience for chemical analysis/organics as per Subpart 55.2-10 (e) (1), (2) or (3)

-OR-

  • an individual with requisite credentials and experience for microbiological and/or biological testing as per Subpart 55.2-10 (h) (1) or (2)

3.  Initial Demonstration of Capability

Applicants will not be required to participate in proficiency testing (PT) studies.  In lieu of a PT requirement, the laboratory must submit an initial demonstration of capability.

The primary analyst will be required to meet the acceptance criteria as referenced in section 9.1 and summarized in Table 10 of EPA method 546. 

For all other analysts, each analyst prepares and analyzes the following:

  • Four (4) replicate lab reagent blanks (LRBs) following acceptance criteria in section 9.1.2 of EPA method 546.
  • Four (4) replicate laboratory fortified blanks at the proposed minimum reporting level (MRL) concentration for the assay following acceptance criteria in section 9.1.1 of EPA method 546.
  • Four (4) replicate laboratory fortified blanks at the action level (4 ppb for ambient water and 0.3 ppb for potable water) following acceptance criteria in section 9.1.1 of EPA method 546.

Questions pertaining to the certification can be sent to elap@health.ny.gov, or Victoria.Pretti@health.ny.gov.

Laboratories approved to test for Total Microcystin

 
ELAP ID LAB NAME CATEGORY (Matrix) LOCATION PHONE #
10472 Erie County Public Health Lab DW,NW 503 Kensington Ave., Buffalo, NY 14214 716-898-6100
10765 NYSDOH Laboratory of Environmental Biology DW,NW Wadsworth Center, Empire State Plaza, Albany, NY 12201 518-473-7925
10771 NYCDEP Hawthorne Laboratory NW 15 Skyline Dr., Hawthorne, NY 10532 914-345-4973
10861 Microbac - Ohio Valley DW,NW 158 Starlite Dr., Marietta, OH 45750 740-373-4071
11398 Eurofins DW,NW 110 South Hill St., South Bend, IN 46617 574-233-4777
11462 Upstate Freshwater Institute DW,NW 224 Midler Park Dr., Syracuse, NY 13206 315-431-4962
12076 Stony Brook University, CCWT-SOMAS South DW,NW 239 Montauk Hwy, Southhampton, NY 11968 848-702-5346
11790 Community Science Institute DW,NW 95 Brown Road / Box 1044, Ithaca, NY 14850 607-257-6606